The SENSOR Basic Bottle Sampling System (BBSS) is designed for safe and reliable closed-loop “grab” sampling of liquids at process pressures less than 150 psig (10 bar). The SENSOR sample valve is designed to operate under continuous flow via a bypass or parallel line off the main process piping. With inclusion of the optional Needle Evacuation System (NES), the BBSS provides for for complete removal of sampling residue from the ID of the Process Needle, therefore preventing plugging and cross-contamination between sampling operations. |
Features and Benefits
• Highly customizable based on process conditions and operator requirements • Primary Flow-Thru Sample Valve features a side-ported needle valve with packing below the threads; ensuring that the stem will not seize due to process build up. • Side-ported Vent Needle prevents plugging of vent port • 316L standard material; other materials available • Replaceable Process and Vent Needles • Non-metallic bottle shroud protects operator in case of shattered bottle • Operation and Installation Manual for each system |
Product Specifications
Materials of Construction
Sample Loop 316L Stainless Steel
Sample Valve 316L; 1/2” flow port
Process Needle 316SS; .083” - .148” OD
Vent Needle 316SS; .083” OD
O-Ring Material Viton standard; optional Kalrez
Seal Material Teflon
Bottle Shroud PVC; 2 oz. - 32 oz.
Retaining Strap Stainless Steel
Mounting Plate Stainless Steel
Operating Pressure 150 psig maximum recommended pressure when sampling;
sample valve and system rated to 2000 psig
Operating Temperature 135°F maximum without cooler;
800°F maximum with cooler and graphoil valve packing
Optional Equipment
SENSOR Needle
Evacuation System (NES): Includes check valve, regulator, rotameter, pressure gauge, and block valve
Emissions Filter: Canister with activated carbon for use when no vent to flare is available; also available with indication crystals which change color to indicate
saturated filter media
Isolation Valves Isolation valves on sample inlet & outlet to allow for easy serviceability
Sample Coolers For use when process temperature exceeds 135°F
Secondary Block Valve Complies with double-block safety requirements
Enclosures Stainless steel enclosures, available uninsulated or insulated and with steam
or electric heater elements; other enclosure materials available
Mounting 2” X 60” pipe stand, galvanized