ThermOmegaTech Scald Protection Valve 1/2HAT/SP-105-C-E 124-302100-105

The HAT/SP self-operating scald protection valve is designed to protect personnel from scalding hot temperatures being released from safety shower and face or eyewash stations.

This email address is being protected from spambots. You need JavaScript enabled to view it.

Operation

The HAT/SP scald protection valve should be installed at the highest point on an emergency safety station to continuously sense and automatically bleed off the excessively hot water. Depending on installation orientation, the thermal actuator at the heart of the valve will sense either the ambient or fluid temperature. It will modulate the valve open to establish flow if the temperature is above the valve’s set-point.

Cooler water from the supply will backfill the line and cause the valve to modulate closed once the water temperature falls to 10°F below the open set-point.

When installed in the ambient sensing position (standard flow), the thermal actuator will respond to atmospheric temperature changes to initiate flow and then respond to water temperature once flow is established.

  • More conservative choice
  • Opens sooner than fluid sensing on dropping temperatures
  • More tolerant of dirty water
  • Good choice for warmer climates

The actuator will always respond to the water temperature when installed in the fluid sensing position (reverse flow).

  • Used as a backup with insulated piping or heat tracing
  • Ideal for colder climates
  • Results in less nuisance dumping/draining

Typical Applications

A safety hazard for plant personnel can occur when utilizing safety showers, facewash, or eyewash stations if overheating the pipes caused by solar radiation or steam/electric tracing results in extremely high temperatures at the point of use. The HAT/SP scald protection valve prevents this safety hazard.

When installed in safety showers, eyewash stations, and other locations exposed to the same source of overheating as the system, the HAT/SP will be heated just as the pipe system. The valve will open to establish flow until the overtemperature water is eliminated and it will then modulate closed.

 

Design Features

  • Exclusive self-actuating Thermoloid® wax blend thermal actuator
  • Stainless steel body, fittings, spring, and plug
  • Compact, low-mass – fast response
  • Corrosion-resistant – long service life
  • Ram-type plug for reliable and tight shutoff
  • Installs in any orientation
 

Benefits

  • Self-operating, no external power source required
  • Meets ANSI Z358.1 standards
  • Protects safety showers from over-temperature conditions, keeping personnel safe
  • Two wrench flats for easy installation
  • Discharges the minimum amount of water required

Ordering

PART NUMBER

DESCRIPTION2

124-302100-XXX

½” HAT/SP-XXX-C-E (Ambient Sensing)

124-312100-XXX

½” HAT/SP-XXX-C-SS-E (Ambient Sensing)

124-702100-XXX

½” HAT/SP-XXX-C-RF-E1(Fluid Sensing)

124-712100-XXX

½” HAT/SP-XXX-C-SS-RF-E (Fluid sensing)

125-502100-XXX

¾” HAT/SP-XXX-D-E (Ambient Sensing)

125-512100-XXX

¾” HAT/SP-XXX-D-SS-E (Ambient Sensing)

125-702100-XXX

¾” HAT/SP-XXX-D-RF-E (Fluid Sensing)

125-712100-XXX

¾” HAT/SP-XXX-D-SS-RF-E1 (Fluid Sensing)

Notes

  1. Reverse flow option for C-port is rated 150 PSIG (10.33 BAR); D-port is 70 PSIG (4.8 BAR)
  2. Standard full open temperature, “XXX”, is 105°F. Optional open temperatures, “XXX”: 95°F, 100°F, 110°F, and 115°F
    1. Closing temperature is typically 10°F below opening temperature
 

Specifications

  • Sizes: ½”, ¾”
  • Maximum Operating Pressure: 200 PSIG (13.8 BAR)
  • Maximum Operating Temperature: 300°F (149°C)

Texas
Corporate Office - Houston Physical Address:
11711 Playa Court
Houston, Texas 77034

Mailing Address
PO Box 890649
Houston, Texas 77289-0649

Tel: (281) 484-4830
Fax: (281) 484-5456
E-Mail: info@techquip.com

Terms and Conditions

Louisiana
State Office - Baton Rouge Physical address:
18212 E. Petroleum Dr. Ste. 3B
Baton Rouge, LA 70810

Mailing Address
18212 E. Petroleum Dr. Ste. 3B
Baton Rouge, LA 70810

Tel: (225) 927-4284
Fax: (225) 295-5995
E-mail: info@techquip.com

Texas Satellite Locations
Beaumont
bmtsales@techquip.com

Corpus Christi
ccsales@techquip.com

Louisiana Satellite Locations
Lake Charles
Tel: (225) 927-4284
lchsales@techquip.com

New Orleans
Tel: (504) 566-4900
nolasales@techquip.com